SBER1238
SBER1238 - REDUCER ELBOW, SOLDER FREE, 3/8" X 1/2"
SB1 Series Quick Connect Refrigerant Fittings are FLAME FREE, Tool FREE and Problem FREE! /they are available as couplers, (45 & 90°) elbows and flares for 1/4" to 7/8" copper tubing. No brazing, tools or nitrogen purge needed for installation.
Features/Benefits
- Approved for Hard Drawn Copper: 1/4" - 7/8" Type ACR, M, L, K
- Approved for Hard Soft Copper (Annealed): 1/4" - 7/8" Type ACR, L, K
- Approved Refrigerants - R134a, R404A, R290, R407A, R600a, R507, R22, R410A, R32, R407C, R448A, R449A, R454B, R500, R1234yf, R1234ze
- C3771 Brass Body
- UL Listed 207, SA #44910 SDTW(7)
- Vibration Resistant Rating UL 1963
- WARNING: Prop 65 info
Continuous Operating Temperature: | 250°F / 121°C |
O-Ring Temperature: | -40°F / 250°F (-40°C / 121°C) |
Maximum Rated Pressure (MRP): | 870 PSI / 60 Bar |
Minimum Burst Pressure : | 3600 PSI / 250 Bar |
Vacuum Pressure Capability: | 30 Microns |
Compatibility-Tubing Tolerance: | ASTM B280, UNI EN 12735 |
Fitting Material: | C3771, Polycarbonate |
O-Ring Material: | Chloroprene |
Connection Size (Inch): | 0.375 x 0.500 |
Length (Inch): | 1.339 |
Outside Diameter (Inch): | 1.181 |
Connection Thread: | None |
Type: | 90° |
Refrigerants |
Glycol |
Non-Potable Water |
SDS | Product Sheets | Cross Reference Information |
no entry | SBER1238_prd_001.pdf |
no entry |
Manuals | Application Sheets | Software |
SBER1238_man_001.pdf |
SBER1238_app_001.pdf |
no entry |
No Cross Reference Available
No Accessories Available
Can SB1s be used with aluminum, steel or stainless steel tubing?: | No, only copper to copper connections |
What is the shelf life of the fittings?: | The manufacturer sets the shelf life @ 30+ years |
Do the fittings need to be insulated after an install?: | Yes, just as you would with any other fitting where it would be subject to condensation. |
What is the #1 cause of problems with the SB1 fittings ?: | Not reading/following the installation instructions |
The SBLM1458 depth gauge only goes up to 5/8” so how do I mark 3/4” & 7/8” tubing?: | Part number SBLMDC3478 is a combo tool, combining both a depth gauge and a disconnect tool |
Do SB1s need to be replaced when retrofitting to a lower GWP refrigerant?: | Yes. The compression set of the super neoprene o?rings may be compromised when transitioning from one refrigerant to another. Always install new fittings. |
Can the fittings be removed and reinstalled on the same spot of tubing?: | The fitting can be installed onto the same spot if the tube is properly sanded and cleaned, removing any etch marks, or replace onto a clean section of tubing. |
What is the warranty on SB1 fittings?: | A 5?year limited warranty policy which is available upon request. |